Additional product information TPI 343/C3 Water Resistant, Dual-input, K-Type Thermocouple Thermometer with Tilt Stand Boot, Carrying Case with Shoulder Strap, Pipe Clamp Temperature Probes, and K-Type Thermocouple Probes with Sub-mini Connection, -50 to 1350 Degrees C, -58 to 2462 Degrees F, Accuracy of + or - 0.3% of Reading Plus 1 Degree C Features
Today Price: Check current price |
Product Description
The TPI 343/C3 water-resistant dual-channel K-type thermocouple digital thermometer with probes is for use in applications requiring a broad range of temperature measurements, including furnaces, kilns, freezers, and other industrial applications. It measures temperature from -50 to 1350 degrees C (-58 to 2462 degrees F), with a best accuracy of + or - 0.3% of reading plus 1 degree C (1.8 degree F). The K-type thermocouple sensor has a broader temperature measurement range than a thermistor sensor but provides lower accuracy. This dual-channel thermometer has two inputs for connecting K-type temperature probes, allowing the operator to measure the temperature of two samples at one time. The thermometer can be calibrated in an ice bath to help preserve measurement accuracy. The LCD screen shows the current temperature, the highest or lowest measurement values for the session, or the difference between two readings. The thermometer can record readings in its internal memory. The operator can choose to display readings in degrees C or F. The hold feature keeps a reading on display so that it can be recorded. Two K-type thermocouple probes with 4' lead and fluorinated ethylene propylene (FEP) insulation are provided for taking measurements, and two pipe clamp probes with 4' leads and a 1.2" maximum jaw opening are provided for taking hands-free measurements. The meter accepts other K-type thermocouple probes with a sub-mini connection. The included rubber boot fits onto the thermometer body to help protect the thermometer from damage due to accidental drops, and the boot has a tilt stand for propping up the thermometer on a flat surface. The thermometer operates on one 9V battery (included). To conserve battery life, the thermometer automatically turns off after 30 minutes of non-use. A low-battery indicator alerts the operator when the batteries need to be changed. A soft, padded carrying case with shoulder strap helps protect the thermometer from damage during transport and storage.
SpecificationsTemperature measurement range, for thermometer-50 to 1350 degrees C (-58 to 2462 degrees F)Temperature measurement range, for K-type thermocouple probe-110 to 204 degrees C (-165 to 400 degrees F)Temperature measurement range, for pipe clamp probes-58 to 482 degrees F (-50 to 250 degrees C)Resolution0.1 or 1 degree FAccuracy+ or - 1.6 degrees C (3 degrees F) at -50 to 0 degrees C (-58 to 32 degrees F); + or - 0.3% of reading plus 1 degree C (1.8 degree F) at 0 to 600 degrees C (32 to 1100 degrees F); + or - 0.4% of reading plus 1 degree C (1.8 degree F) at 600 to 1350 degrees C (1100 to 2462 degrees F)Power supply9V battery (one, included)Weight278 g (9.8 oz.)Dimensions*152 x 77 x 41 mm/6 x 3 x 1.6 in. (H x W x D)*H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.
Digital thermocouple thermometers measure the temperature of air, liquids, or surfaces. They may measure temperature in Celsius, Fahrenheit, or see details
TPI 343/C3 Water Resistant, Dual-input, K-Type Thermocouple Thermometer with Tilt Stand Boot, Carrying Case with Shoulder Strap, Pipe Clamp Temperature Probes, and K-Type Thermocouple Probes with Sub-mini Connection, -50 to 1350 Degrees C, -58 to 2462 Degrees F, Accuracy of + or - 0.3% of Reading Plus 1 Degree C TPI.
Features
- Digital thermometer with probes for applications requiring a broad range of temperature measurements, including furnaces, kilns, freezers, and other industrial applications
- Measures temperature from -50 to 1350 degrees C (-58 to 2462 degrees F), with a best accuracy of + or - 0.3% of reading plus 1 degree C (1.8 degree F)
- K-type thermocouple sensor has a broader temperature measurement range than a thermistor sensor
- Dual-channel thermometer has two inputs for connecting K-type temperature probes, allowing the operator to measure the temperature of two samples at one time
- Thermometer can be calibrated in an ice bath to help preserve measurement accuracy
Fast Buying choice:
You can buy TPI 343/C3 Water Resistant, Dual-input, K-Type Thermocouple Thermometer with Tilt Stand Boot, Carrying Case with Shoulder Strap, Pipe Clamp Temperature Probes, and K-Type Thermocouple Probes with Sub-mini Connection, -50 to 1350 Degrees C, -58 to 2462 Degrees F, Accuracy of + or - 0.3% of Reading Plus 1 Degree C the best price with supersaver shipping. For more discounts, delivery availableOptions and additional information on the link below Click Get it Now!